Great Water Filters Blog

Reverse Osmosis System Waste Water Ratio and Your Water Bill

Written by Great Water Filters | Nov 25, 2026, 10:05:33 AM

Great Water Filters can help you understand how a reverse osmosis system’s wastewater ratio may affect your water use and choose a system that suits your needs. A system can send around 3 to 5 litres of wastewater down the drain for every litre of purified water, with 4:1 a useful representative ratio. The ratio is one part of the picture when considering your water bill.

It’s reasonable to wonder whether the extra water will increase household costs. In a metered home, reject water still counts as supplied water, so the amount an RO system sends to the drain can contribute to usage charges. The impact depends on how much treated water you use and the system’s actual waste-to-product ratio.

We’ll help you understand how to read a reverse osmosis system waste water ratio, what can affect it, and how to consider its effect on water use in an Australian home. You’ll also learn about possible non-drinking uses for reject water and why it should not be treated as drinking water.

Key Takeaways

  • Learn how to read the ratio of wastewater to purified water, so you can understand what it means for your household’s water use.
  • See how membrane capacity and flow restrictor sizing work together to influence your system’s performance.
  • Understand how feed pressure, water temperature and water quality can change the amount of water sent to waste.
  • Find out which everyday uses may suit RO reject water, and why it shouldn’t be used for drinking.
  • Compare the factors behind wastewater ratios in conventional, high-efficiency and tankless systems.

Can You Reuse RO Wastewater?

Yes. Reverse osmosis reject water may suit some non-drinking uses, such as toilet flushing, floor cleaning and watering plants. Whether it’s suitable depends on the intended use and what the water contains after filtration. We can help you understand your system and its options.

Reject Water Reuse Options

You may be able to collect reject water for toilet flushing, floor cleaning or watering plants instead of sending it straight to the drain. This can make more use of the water entering your home, but reject water isn’t purified and may contain contaminants. Industrial systems can also recirculate 50% or more of wastewater, reducing how much leaves the process. Household reuse and industrial recirculation are different approaches, but both can treat reject water as a potential resource.

Interpreting Reject-to-Treated-Water Ratios

A reject-to-treated-water ratio compares wastewater discharged with purified water produced. Read the figures in that order: a 3:1 ratio means three litres of reject for every litre of treated water. The system therefore takes in four litres in total, assuming only those two streams are counted. Check the ratio convention when comparing systems, as a product-to-reject ratio reverses the order and can make the same water balance look different.

To compare systems, use the same order and units for both figures. For example, compare litres of reject water per litre of treated water, rather than treated water per litre of reject water. A tankless design still uses the same ratio convention: it describes the two water streams, not whether the system stores treated water. We can help you check the figures.

Estimating Reject-Water Volumes

Estimate reject volume by multiplying treated water used by the reject-to-treated ratio. At a 3:1 ratio, one litre of treated water corresponds to three litres of reject. For a daily estimate, multiply that result by daily treated-water use; for an annual estimate, multiply the daily reject volume by 365.

For example, producing one gallon of treated water daily with a 3:1 system results in 1,095 gallons of reject water per year. This estimate reflects the stated ratio and daily use. Actual totals can vary with system performance or household demand, so use figures that match your system’s measured operation. We can help you understand the calculation.

Purified Water and Reject Water

Treated water is intended for uses such as drinking. Reject water is the concentrated stream discharged during reverse osmosis. The membrane separates the streams, with reject water carrying material removed from the treated water. That’s why reuse should be limited to non-drinking purposes.

A 50-litre example makes the difference clear: a system receiving 100 litres of feedwater can produce 50 litres of treated water and 50 litres of concentrate. The two outputs aren’t interchangeable. Use reject water only for an appropriate purpose, such as floor cleaning or toilet flushing, not drinking or preparing food.

Does reverse osmosis make your water bill go up?

Yes. An RO system directs feedwater towards both treated water and the drain, so reject water contributes to metered household use. We can help you choose a suitable setup and keep it running as intended. This includes keeping the membrane clean, replacing pre-filters on schedule and using a flow restrictor matched to the membrane’s capacity. There’s no need to alter the restrictor, as its sizing affects system operation.

An RO membrane separates water into a treated stream and a reject stream. Its pores are listed at 0.0001 micron; water passes through, while concentrated material leaves with the reject flow. The reverse osmosis system’s waste water ratio affects your water use, alongside how much treated water your household draws. We can help you choose a setup that suits your household and understand how membrane condition and fouling can affect performance over time.

A flow restrictor controls reject-water flow and must suit the membrane’s rated capacity. We can help you find the right pairing:

  • 8-20 GPD membrane: 150 ML per minute flow restrictor.
  • 21-25 GPD membrane: 250 ML per minute flow restrictor.
  • 36 GPD membrane: 350 ML per minute flow restrictor.
  • 50 GPD membrane: 500 ML per minute flow restrictor.
  • 75 GPD membrane: 750 ML per minute flow restrictor.
  • 100 GPD membrane: 1000 ML per minute flow restrictor.
  • 150 GPD membrane: 1200 ML per minute flow restrictor.

For example, a 50 GPD membrane is paired with a 500 ML per minute restrictor, not the 1000 ML per minute pairing listed for a 100 GPD membrane. We can help match these components, so you don’t need to rely on a mismatched part to reduce drain flow.

Membrane condition also affects how consistently an RO system produces water. Fouling and scaling can interfere with operation, while a clean membrane supports efficient filtration. The suggested flushing practice is to run the membrane at full flow for a few minutes at least once a month. We can help you keep up with this routine; changing the flow restrictor to pursue a lower wastewater figure is not a substitute.

Pre-filters protect the membrane by treating feedwater before it reaches the membrane. Replace RO pre-filters every 6 to 12 months, and include membrane flushing in your maintenance routine. A residential RO membrane typically lasts 2-3 years before replacement, but timely filter changes and membrane care can help prevent excessive water loss. We can look after you with guidance on these maintenance steps, while keeping the system operating as intended.

For help choosing a suitable residential RO setup, talk with a water filtration specialist about membrane capacity, flow restrictor sizing and ongoing filter maintenance.

How feed pressure and water temperature affect waste

Feed pressure and water temperature influence how much water passes through the membrane and how much leaves as reject water. A system’s rated ratio applies to specified conditions. Actual recovery can vary as pressure, temperature, feedwater quality and maintenance change.

Pressure provides the force that moves water through the membrane. The ideal feed-water pressure range is 60 to 70 psi. Under lower pressure, a system rated to produce one gallon of purified water for one gallon of reject water may produce closer to one gallon of purified water for every two or three gallons rejected. That changes the amount entering the drain for the same treated-water output.

Colder feedwater can slow production through the membrane. If treated-water production falls while reject flow continues, the measured waste-to-product ratio can rise. This is one reason a system may not match its rated ratio in different operating conditions. Pressure and temperature work together, so cold water combined with lower pressure can affect actual recovery more than either factor alone.

Total dissolved solids, or TDS, describe the concentration of dissolved material in feedwater. Above 500 ppm TDS, osmotic pressure increases, and the system requires more water to produce permeate. That extra resistance can increase reject-water volume relative to treated output. Hardness matters too: higher recovery can increase scaling risk when source water has high hardness, so reducing drain flow isn’t always the only performance consideration.

Maintenance and operation also affect water consumption. Fouling, scaling and membrane condition can alter recovery, while feedwater quality and system configuration influence the result. A dirty or worn membrane may perform differently from a clean one operating at its intended pressure. Regular maintenance helps address these factors, but low pressure, cold water and high-TDS feedwater can still affect performance.

Recovery provides a useful way to compare the two water streams. Calculate it as treated water divided by total feedwater, multiplied by 100. For example, a system producing one gallon of treated water and three gallons of reject water uses four gallons of feedwater. Its recovery is 25 per cent. A higher reject volume means a lower recovery percentage for that example.

For a fair comparison, use the same units and ratio order each time. A figure in gallons cannot be compared directly with one in litres without converting units. Also distinguish reject-to-treated water from treated-to-reject water: reversing the order changes the meaning. Pressure, temperature, TDS, hardness and membrane condition can help explain why actual results differ from a rating.

Wastewater ratios in high-efficiency and tankless systems

High-efficiency and tankless designs may reduce reject water, but labels don’t tell the whole story. In Australia, compare performance ratings with local requirements. NSF/ANSI 58 covers RO recovery and efficiency ratings, while the US EPA WaterSense program sets criteria for eligible systems.

Comparing Standard and High-Efficiency Systems

Systems differ in how much feedwater becomes treated water rather than reject. Some advanced systems can reach a 1:1 waste-to-pure-water ratio, while modern high-efficiency models may reduce wastewater by up to 80%. For a fair comparison, check that the ratio order and operating conditions are the same.

Tankless describes how water is stored, not how efficiently a system operates. Wastewater performance depends on the membrane and system configuration. Tank-based units store treated water, and pressure in the tank can affect production as it fills. A rating may not reflect every operating condition.

Recovery and Efficiency Ratings

Recovery measures the share of feedwater that becomes treated water. An efficiency rating may describe reject volume relative to treated output. As these measures use different calculations, check the ratio and conditions before comparing ratings or estimating household water use.

For example, a 1:1 reject-to-pure-water ratio means one unit of reject for each unit of pure water. That represents two units of feedwater, with half becoming treated water. A 1:1 pure-to-drain ratio describes something different, so check the order of the ratio.

WaterSense uses a reject-water limit of 2.3 gallons per treated gallon for eligible systems. This is a US programme criterion, not an Australian regulation or universal product rating. NSF/ANSI 58 covers recovery and efficiency procedures, but real-world results can vary.

Tankless systems have no storage tank, but that alone doesn’t mean lower water use. Compare the reject-to-treated ratio, recovery method and conditions behind each rating. Feedwater, membrane condition and operating patterns can affect actual output. To compare environmental impact, consider the ratio alongside household demand rather than relying on “high efficiency” or “tankless” labels.

Reverse osmosis waste-to-product water ratios

A waste-to-product ratio shows how much concentrate an RO system discharges for each amount of treated water it produces. Residential systems are described as producing 3 to 5 parts of wastewater per part of pure water, with 4:1 given as an average. Use the ratio to compare water use between systems.

Read the figures in the stated order. A 2:1 concentrate-to-treated-water ratio means two litres of reject for every litre of product water. If a label lists pure water first, the same figures mean something different. Check which stream comes first and keep units consistent, such as litres per litre.

For example, at 5:1, producing 100 litres of treated water discharges 500 litres of concentrate. At 2.3:1, the same output produces 230 litres of concentrate; at 1:1, it produces 100 litres. A lower ratio means less reject for the same treated output.

Compare the ratio with your household’s daily water use. If demand doubles at a 4:1 ratio, reject water also doubles. The ratio and the volume you use together determine total drain flow.

Reverse osmosis differs from filtration methods that do not create separate treated-water and reject streams. RO pushes water through a membrane, producing treated water and a concentrated stream that is discharged or managed separately. Other methods may use water during operation or maintenance, but their water use is not always expressed as a waste-to-product ratio. Compare methods with their different processes in mind.

A ratio describes water volume, not every aspect of filtration performance. It does not show which dissolved substances are reduced, the quality of the treated water or how the system performs with different feedwater. For a useful comparison, consider the ratio alongside daily demand, system operation and the intended use of the treated water.

In short, a lower reject-to-product figure means less reject water for the same treated output. Actual household use depends on both the ratio and the volume produced. Compare like with like, and check the order of the figures to assess wastewater without confusing water efficiency with filtration performance.

Explore reverse osmosis options with confidence

Great Water Filters: Elite Series 3 Reverse Osmosis Water Filter System

The Elite Series 3 Reverse Osmosis Water Filter System is a residential option for households considering reverse osmosis filtration. Great Water Filters supplies and professionally installs this system, offering professional installation across our service areas.

For a simpler installation experience, the offer includes transparent upfront pricing, no upfront payment required and “only pay when fully installed & happy.” Great Water Filters describes this as “100% no risk” and offers smarter & healthier water filter systems.

Contact Great Water Filters to discuss whether the Elite Series 3 suits your household.

Get help finding the right water setup for your home

Great Water Filters can help assess your needs and the best filtration approach for your home. For drinking water, we can consider the reverse osmosis system waste water ratio alongside your household’s needs and the system’s operating conditions. For broader household water treatment, the ES5Q Hi Flow Wellness Whole House Water Filter System and Whole House Water Filter Softener are other options.

Great Water Filters offers the Elite Series 3 Reverse Osmosis Water Filter System, the ES5Q Hi Flow Wellness Whole House Water Filter System and the Whole House Water Filter Softener. We can discuss your priorities and help clarify which type of system best fits your home, without making wastewater performance the only deciding factor.

Contact Great Water Filters for advice

We’ll assess the water you want to treat and how you plan to use it, then help you make a considered choice with confidence.

Frequently Asked Questions

Where Does RO Wastewater Come From?

RO wastewater is the reject stream created when feedwater passes through the system’s membrane. It carries material removed during filtration and usually flows to the drain, unless collected for a suitable non-drinking use. The volume depends on treated water output and operating conditions.

How Much Water Is Wasted?

The amount varies by system and use. Most reverse osmosis units produce 1 to 6 gallons of wastewater for each gallon of purified water. To estimate your system’s output, multiply the purified water volume you use by its reject-to-treated ratio. For example, two litres of treated water at a 3:1 reject ratio would discharge six litres of reject water.

What Do Different RO Wastewater Ratios Mean?

Check which stream comes first: 2:1 reject-to-treated means two units of wastewater for each unit of purified water. A product-to-reject ratio reverses the order. For a fair comparison, use the same order and units for both systems, and check whether the figures describe rated or measured operation.

What is the typical wastewater-to-pure-water ratio for a reverse osmosis system?

Residential RO systems commonly produce 3 to 5 parts wastewater for each part of pure water, with 4:1 given as an average. This is a guide, not a fixed result. Actual output can vary with feed pressure, water temperature, dissolved solids, membrane condition and daily production needs.

How many litres of wastewater does a home reverse osmosis system produce per litre of filtered water?

A typical reference point is about three litres of wastewater per litre of treated water. Residential systems may produce three to five parts wastewater for each part treated, so one litre of filtered water could mean three to five litres of reject water. Check the order stated in the system’s reverse osmosis wastewater ratio.

How do tank-based and tankless reverse osmosis systems compare in wastewater ratio?

A tank-based system stores treated water; a tankless system produces it without a storage tank. The design alone doesn’t determine which has the lower wastewater ratio. Compare each unit’s reject-water volume with its treated-water output, using the same units and ratio order. Results also depend on the membrane, system configuration and operating conditions.

What factors affect reverse osmosis wastewater ratio, such as water pressure and temperature?

Feed pressure, water temperature, dissolved solids and membrane condition can all affect the ratio. Lower pressure, colder feedwater or higher TDS can reduce membrane production relative to reject flow. Fouling and scaling can also change recovery, so systems with similar ratings may perform differently in different household water conditions.

How does feed-water pressure change reverse osmosis water recovery and waste?

Pressure drives feedwater through the membrane. Lower pressure can mean less treated water for the reject flow. The ideal feed-water pressure range is 60 to 70 psi. Below this, a system rated for one gallon of purified water per gallon of reject may produce closer to one gallon of purified water for every two or three gallons rejected.